Data Centre Cooling
DATACOOL-PACKAGE Precision Temperature Control Unit with Built-in Fresh Air Free Cooling
DATACOOL-PACKAGE Temperature control unit with built-in fresh air free cooling system is specially designed for small/medium data center and electronic equipment room. By integrating numerous advantages and latest technologies of current computer-room TCU, the unit can provide the values exceeding expectations for the key environment users. DATACOOL-PACKAGE is a self-contained temperature control unit which realizes easy installation without any refrigeration piping connection.DATACOOL-PACKAGE can maximumly works in free cooling mode with the lowest power consumption, saving huge energy and lowering the operation cost.
CAPACITY: 9.1~48.6kW APPLICATION: Small to mid-size switching room for telecommunicationSmall to mid-size data center and computer roomUPS and battery roomIndustrial process control center FEATURES: Energy Saving When the temperature difference between indoor and outdoor is higher than 10℃, the built-in free cooling system can supply 100% of the cooling capacity, saving 90% energy. High Flexibility Good structure design and easy maintenanceThe unit can be fully maintained from the front.Offer two structure types: packaged and segmental structure. Packaged structure facilitates the installation. Segmental structure includes main unit and fan box. Fan box should be assembled with main unit at worksite, but it is easier for transport. High sensible heat ratio The Sensible heat ratio of all the units are higher than 0.9.Wide working range(-30°C~45°C) Corrosion-proof The unit frame and panels are coated with the corrosion proof epoxy powder.High efficiency EC fan with high torque and low leakage air damper. Fully automatic control Equipped with a full automatic control system.automatically selects mechanic cooling or free cooling according to the temperature of indoor side and outdoor side. The controller will change the working unit automatically to balance the working time of the 2 units.Be capable of automatic reversion to the fresh air cooling mode upon mechanical failure.Random restart when power recovered The attend mode function When service people is working in base station, he can simply press 2 buttons on the controller interface, then the control temperature of the TCU will be set as 24℃ (settable) automatically. Half an hour later (settable) the control temperature of TCU will be returned to original set point.4 levels password protection, voltage protection, alarms, providing the unit with full protection. Automatic self-diagnosis The unit is provided with an automatic self-diagnosis procedure and the service worker can start the check only by pressing a button. Running data logging If the interval of data logging is less than 5 minutes, the controller can store at least 48 hours working data.Remote monitoring of Web server card to know the operation state of the unit and conduct the remote control.