Data Centre Cooling
INNOVA Container Data Center
INNOVA series container data center products in terms of their product positioning, product architecture, product features, composition, configuration samples and application scenarios. Model of INNOVA series container data center product is as follows: • TEU: about 20 ft containers, with 6 IT cabinets, and total IT load of no more than 60kW • FEU: about 40 ft containers, with 10 IT cabinets, and total IT load of no more than 100kW
CAPACITY: 25kW/ set, total 4 set APPLICATION: ● Transmission Network ● Convergence & Core Network ● Edge Computing ● New and renovated old equipment room ● Distributed,mobile,single module deployment ● Energy ● Govemment ● Enterprises FEATURES: The integrated cabinet system, power supply and distribution system, cooling system, monitoring system and cabling system adopt high integration design, which can provide one-stop packged data center solution; Different power supply currents are set for servers, storage, network devices and distribution cabinets to support mixed density networking; The maximum power of single rack is 10kW, which can meet different business needs of customers; High reliability and safety Grounding: the overall grounding overlap mode has a good anti-electromagnetic interference capability, the Electromagnetic Compatibility (EMC) specifications conform to the Class A technical requirements of CISPR22/EN55022 standard. Dustproof and waterproof: The integral protection of the data center adopts ISO (International Organization for Standardization) 668 standard prefabricated modules that are produced with mature welding skills in the field to achieve IP55 dustproof and waterproof. Fire extinguishing system: efficient and safe fire extinguishing system, with the advantages of high reliability, clean and non-toxic, insulation and environmental protection, etc. has been adopted, to extinguish the fire efficiently and safely, avoid damaging the equipment, and ensure the high availability of the equipment in the case of fire. The fire extinguishing agent of the firefighting system adopts Heptafluoropropane(FM200). Intelligent access control management system and mechanical lock has been applied for multiple security protection, which can avoid the entrance of irrelevant personnel. High reliability level, supporting up to Tier 4 configuration of international standard TIA-942, or level A/B/C of Chinese standard GB50174; Backup time can be controlled and both built-in battery and external battery can be used; UPS is equipped with manual maintenance bypass. During normal operation, the manual maintenance bypass switch is locked to avoid electrical accidents caused by misoperation; Modular UPS can achieve reliable N+1 redundancy, improving the reliability of the system; Optical fiber and network cable are separated to reduce electromagnetic interference; Cables meet the high grade CMP/OFNP high flame retardant performance, completely consistent with the standard of international class A, which is safe and reliable.